We've updated our Terms of Use and Privacy Policy. Please review. x

Create an Intelligent Cart - save more with iCart items.

x

Cisco SG300-10PP 10-port Gigabit PoE+ Managed Switch

In iCart
$337.00
Qty
    icartitem
    You can save on shipping costs by selecting items that can be shipped together.
    Add To Cart

    Product Description

    description is currently unavailable for this product.

    Product Details

    • Text-Editable Config Files Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deployment
    • Congestion Avoidance A TCP congestion avoidance algorithm is required to minimize and prevent global TCP loss synchronization
    • Cable Length Detection Adjusts the signal strength based on the cable length for Gigabit Ethernet models. Reduces the power consumption for cables shorter than 10m
    • Auto Smartports Applies the intelligence delivered through the Smartport roles and applies it automatically to the port based on the devices discovered over CDP or LLDP-MED. This facilitates zero touch deployments
    • STP Bridge Protocol Data Unit Guard A security mechanism to protect the network from invalid configurations. A port enabled for BPDU Guard is shut down if a BPDU message is received on that port
    • IPv6 Applications Web/SSL, Telnet server/SSH, ping, traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), SNMP, RADIUS, syslog, DNS client, Telnet Client, DHCP Client, DHCP Autoconfig, IPv6 DHCP Relay, TACACS
    • Standards (Cont.) RFC 919, RFC 922, RFC 920, RFC 950, RFC 1042, RFC 1071, RFC 1123, RFC 1141, RFC 1155, RFC 1157, RFC 1350, RFC 1533, RFC 1541, RFC 1624, RFC 1700, RFC 1867, RFC 2030, RFC 2616, RFC 2131, RFC 2132, RFC 3164, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2576, RFC 4330, RFC 1213, RFC 1215, RFC 1286, RFC 1442, RFC 1451, RFC 1493, RFC 1573, RFC 1643, RFC 1757, RFC 1907, RFC 2011
    • Spanning Tree Protocol (STP) Standard 802.1d Spanning Tree supportFast convergence using 802.1w (Rapid Spanning Tree [RSTP]), enabled by default8 instances are supportedMultiple Spanning Tree instances using 802.1s (MSTP)
    • Classless Inter-Domain Routing (CIDR) Support for CIDR
    • Web Based Authentication Web based authentication provides network admission control through web browser to any host devices and operating systems
    • DHCP DHCP Options facilitate tighter control from a central point (DHCP server) to obtain IP address, auto-configuration (with configuration file download), DHCP relay, and hostname (Options 12, 66, 67, 82, 129, and 150)
    • DHCP relay at Layer 3 Relay of DHCP traffic across IP domains
    • Fast Ethernet Ports 8 10/100/1000 PoE+ ports with 62W power budget2 Combo mini-GBIC ports
    • Layer 3 Interface Configuration of layer 3 interface on physical port, LAG, VLAN interface or Loopback interface
    • Link Layer Discovery Protocol (802.1ab) LLDP allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phones (with LLDP-MED extensions)
    • Secure Sensitive Data (SSD) A mechanism to manage sensitive data (such as passwords, keys, etc) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plaintext or encrypted is provided according to the user configured access level and the access method of the user
    • Certification UL (UL 60950), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A
    • Secure Core Technology (SCT) Ensures that the switch will receive and process management and protocol traffic no matter how much traffic is received
    • RJ-45 Ports 8 Gigabit Ethernet
    • Q-in-Q VLAN VLANs transparently cross a service provider network while isolating traffic among customers
    • Dimensions (WxHxD) 11 x 1.45 x 6.7" (279.40 x 36.83 x 170.18mm)
    • STP Root Guard This prevents edge devices not in the network administrator's control from becoming Spanning Tree Protocol root nodes
    • MAC Table Up to 16K (16384) MAC addresses
    • SNMP SNMP versions 1, 2c, and 3 with support for traps, and SNMP version 3 user-based security model (USM)
    • Scheduling Strict priority and weighted round-robin (WRR)Queue assignment based on DSCP and class of service (802.1p/CoS)
    • Secure Shell (SSH) Protocol SSH is a secure replacement for Telnet traffic. SCP also uses SSH. SSH v1 and v2 are supported
    • Operating Temperature 32 to 113 deg. F (0 to 45 deg. C)
    • Dynamic ARP Inspection (DAI) The switch discards ARP packets from a port if there is no static or dynamic IP/MAC bindings or if there is a discrepancy between the source or destination address in the ARP packet. This prevents man-in-the-middle attacks
    • DHCP Relay at Layer 2 Relay of DHCP traffic to DHCP server in different VLAN. Works with DHCP Option 82
    • Cisco Discovery Protocol (CDP) The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics via CDP
    • Smartports Simplified configuration of QoS and security capabilities
    • DHCP Snooping Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces. This prevents rogue devices from behaving as a DHCP Server
    • Disable Port LEDs LEDs can be manually turned off to save on Energy
    • Port Mirroring Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 8 source ports can be mirrored to one destination port. A single session is supported
    • Web User Interface Built-in switch configuration utility for easy browser-based device configuration (HTTP/HTTPS). Supports configuration, system dashboard, system maintenance, and monitoring
    • Voice VLAN Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoSAuto voice capabilities deliver network-wide zero touch deployment of voice endpoints and call control devices
    • VLAN Support for up to 4096 VLANs simultaneously Port-based and 802.1Q tag-based VLANs MAC-based VLANManagement VLANPrivate VLAN Edge (PVE), also known as protected ports, with multiple uplinksGuest VLAN Unauthenticated VLANDynamic VLAN assignment via Radius server along with 802.1x client authenticationCPE VLAN
    • Power Savings Mode Energy Detect, Short Reach
    • Total System Ports 10 Gigabit Ethernet
    • Jumbo Frames Up to 9K (9216) bytes
    • Localization Localization of GUI and documentation into multiple languages
    • IPv4 and IPv6 Dual Stack Coexistence of both protocol stacks to ease migration
    • Cabling Type Unshielded twisted pair (UTP) Category 5 or better for 10BASE-T/100BASE-TXUTP Category 5 Ethernet or better for 1000BASE-T
    • Rate Limiting Ingress policer Egress shaping and rate control Per VLAN, per port, and flow based
    • VLAN Mirroring Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 8 source VLANs can be mirrored to one destination port. A single session is supported
    • IPv6 ACL Drop or rate limit IPv6 packets in hardware
    • Storm Control Broadcast, multicast, and unknown unicast
    • Number of Ports Support PoE 8
    • Combo Ports (RJ-45 + SFP) 2 Gigabit Ethernet combo
    • Cloud Services Support for Cisco Small Business FindIT Network and Cisco OnPlus
    • IEEE 802.1X (Authenticator Role) 802.1X: RADIUS authentication and accounting, MD5 hash, Guest VLAN, Unauthenticated VLAN, Single/multiple host mode and single/multiple sessionsSupports time-based 802.1X Dynamic VLAN assignment
    • Other Management Traceroute Single IP management HTTP/HTTPS SSH RADIUS Port mirroring TFTP upgrade DHCP client BOOTP SNTP Xmodem upgrade Cable diagnostics Ping Syslog Telnet client (SSH secure support)
    • Bonjour The switch advertises itself using the Bonjour protocol
    • IPv6 First Hop Security RA guardND inspectionDHCPv6 guardNeighbor binding table (Snooping and static entries)Neighbor binding integrity check
    • Class of Service Port based 802.1p VLAN priority based IPv4/v6 IP precedence/type of service (ToS)/DSCP based Differentiated Services (DiffServ) Classification and re-marking ACLs, trusted QoS
    • IP/Mac/Port Binding (IPMB) The features (DHCP Snooping, IP Source Guard, and Dynamic ARP Inspection) above work together to prevent DOS attacks in the network, thereby increasing network availability
    • ACLs Support for up to 512 rulesDrop or rate limit based on source and destination MAC, VLAN ID or IP address, protocol, port, differentiated services code point (DSCP)/IP precedence, TCP/UDP source and destination ports, 802.1p priority, Ethernet type, Internet Control Message Protocol (ICMP) packets, IGMP packets, TCP flag, Time-based ACLs supported
    • IPv4 Routing Wirespeed routing of IPv4 packetsUp to 512 static routes and up to 128 IP interfaces
    • Switching Capacity and Forwarding Rate Capacity in Millions of Packets per Second (64-byte packets): 14.88MppsSwitching Capacity in Gigabits per Second: 20.0Gbps
    • Minimum Requirements Web browser: Mozilla Firefox version 8 or later; Microsoft Internet Explorer version 7 or later, Safari, ChromeCategory 5 Ethernet network cableTCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in the network
    • Energy Detect Automatically turns off power off on Gigabit Ethernet and 10/100 RJ-45 port when detecting link downActive mode is resumed without loss of any packets when the switch detects the link up
    • Power Dedicated to PoE 62W (PoE+ supported)
    • IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router
    • GVRP/GARP Protocols for automatically propagating and configuring VLANs in a bridged domain
    • Head-of-Line (HOL) Blocking HOL blocking prevention
    • IGMP Versions 1, 2, and 3 Snooping IGMP limits bandwidth-intensive multicast traffic to only the requesters supports 1K multicast groups (source-specific multicasting is also supported)
    • Operating Humidity 10% to 90%, relative, noncondensing
    • LEDs System, Link/Act, PoE, Speed, LED power saving option
    • Power 100-240V 50-60Hz, 2A, external
    • Multicast Listener Discovery Snooping Deliver IPv6 multicast packets only to the required receivers (MLD v1/2)
    • IPv6 IPv6 host modeIPv6 over Ethernet Dual IPv6/IPv4 stackIPv6 neighbor and router discovery (ND) IPv6 stateless address auto-configurationPath maximum transmission unit (MTU) discoveryDuplicate address detection (DAD) ICMP version 6IPv6 over IPv4 network with Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) supportUSGv6 and IPv6 Gold Logo certified
    • IPv6 QoS Prioritize IPv6 packets in hardware
    • Multicast TV VLAN Multicast TV VLAN allows the single multicast VLAN to be shared in the network while subscribers remain in separate VLANs (Also known as MVR)
    • Remote Monitoring (RMON) Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis
    • Port Security The ability to lock Source MAC addresses to ports, and limits the number of learned MAC addresses
    • Unidirectional Link Detection (UDLD) UDLD monitors physical connection to detect unidirectional links caused by incorrect wiring or cable/port faults to prevent forwarding loops and blackholing of traffic in switched networks
    • Autoconfiguration with SCP File Download Enables secure mass deployment with protection of sensitive data
    • Standards IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3ad LACP, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, IEEE 802.1D (STP, GARP, and GVRP),IEEE 802.1Q/p VLAN, IEEE 802.1w RSTP, IEEE 802.1s Multiple STP, IEEE 802.1X Port Access Authentication, IEEE 802.3af, IEEE 802.3at, RFC 768, RFC 783, RFC 791, RFC 792, RFC 793, RFC 813, RFC 879, RFC 896, RFC 826, RFC 854, RFC 855, RFC 856, RFC 858, RFC 894
    • User Datagram Protocol (UDP) Relay Relay of broadcast information across Layer 3 domains for application discovery or relaying of BootP/DHCP packets
    • Secure Sockets Layer (SSL) SSL support: Encrypts all HTTPS traffic, allowing highly secure access to the browser-based management GUI in the switch
    • Buttons Reset button
    • Textview CLI Scriptable command-line interface. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 is supported for the CLI
    • CPU Memory 128MB
    • DHCP Server Switch functions as an IPv4 DHCP Server serving IP addresses for multiple DHCP pools/scopesSupport for DHCP options
    • Packet Buffer 8MB
    • DoS Prevention Denial-of-Service (DOS) attack prevention
    • Secure Copy (SCP) Securely transfer files to and from the switch
    • Flash 16MB
    • MTBF at 40deg. C (Hours) 945,042
    • System Power Consumption 110V=13.37W220V=12.99W
    • RADIUS Accounting The RADIUS accounting functions allow data to be sent at the start and end of services, indicating the amount of resources (such as time, packets, bytes, and so on) used during the session
    • Port Grouping Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)Up to 8 groups, Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad link aggregation
    • Firmware Upgrade Web browser upgrade (HTTP/HTTPS) and TFTP and upgrade over SCP running over SSH Upgrade can be initiated through console port as well Dual images for resilient firmware upgrades
    • Storage Temperature -4 to 158 deg. F (-20 to 70 deg. C)
    • Power Consumption (with PoE) 110V=83.47W220V=81.58W
    • RADIUS/TACACS+ Supports RADIUS and TACACS authentication. Switch functions as a client
    • Login Banner Configurable multiple banners for web as well as CLI
    • blob PoE Switches & Modules
    • Layer 2 Isolation PVE PVE (also known as protected ports) provides Layer 2 isolation between devices in the same VLAN, supports multiple uplinks (with community VLAN)
    • Time-Based Port Operation Link up or down based on user-defined schedule (when the port is administratively up)
    • IP Source Guard (IPSG) When IP Source Guard is enabled at a port, the switch filters out IP packets received from the port if the source IP addresses of the packets have not been statically configured or dynamically learned from DHCP snooping. This prevents IP Address Spoofing
    • Priority Levels 4 hardware queues
    • Storage Humidity 10% to 90%, relative, noncondensing
    • Heat Dissipation 278.36 BTU/hr

    Reviews (0)